File: //usr/local/MegaRAID Storage Manager/Languages/en/MR_Events.properties
##############################################################################
#This property file contains the English language strings for all MSM events # #
# MR_EVENTS_DETAILS(PROPERTIES FILE) #
# #
##############################################################################
0 = Controller ID: {0} Firmware initialization started: (PCI ID {1}/{2}/{3}/{4})
1 = Controller ID: {0} Image version {1}
2 = Controller ID: {0} Unable to recover cache data from TBBU
3 = Controller ID: {0} Cache data recovered from TBBU successfully
4 = Controller ID: {0} Configuration cleared
5 = Controller ID: {0} Cluster down; communication with peer lost
6 = Controller ID: {0} Logical drive ownership changed: VD = {1} Previous = {2} Current = {3}
7 = Controller ID: {0} Alarm disabled by user
8 = Controller ID: {0} Alarm enabled by user
9 = Controller ID: {0} Background initialization rate changed: {1}%
10 = Controller ID: {0} Controller cache discarded due to memory/battery problems
11 = Controller ID: {0} Unable to recover cache data due to configuration mismatch
12 = Controller ID: {0} Cache data recovered successfully
13 = Controller ID: {0} Controller cache discarded due to firmware version incompatibility
14 = Controller ID: {0} Consistency Check rate changed: {1}%
15 = Controller ID: {0} Fatal firmware error: {1}
16 = Controller ID: {0} Factory defaults restored
17 = Controller ID: {0} Flash downloaded image corrupt
18 = Controller ID: {0} Flash erase error
19 = Controller ID: {0} Flash timeout during erase
20 = Controller ID: {0} Flash error
21 = Controller ID: {0} Flashing image: {1}
22 = Controller ID: {0} Flash of new firmware image(s) complete
23 = Controller ID: {0} Flash programming error
24 = Controller ID: {0} Flash timeout during programming
25 = Controller ID: {0} Flash chip type unknown
26 = Controller ID: {0} Flash command set unknown
27 = Controller ID: {0} Flash verify failure
28 = Controller ID: {0} Flush rate changed: {1} Seconds
29 = Controller ID: {0} Hibernate command received from host
30 = Controller ID: {0} Event log cleared
31 = Controller ID: {0} Event log wrapped
32 = Controller ID: {0} Multi-bit ECC error:ECAR = {1} , ELOG = {2} ,({3})
33 = Controller ID: {0} Single-bit ECC error:ECAR = {1} , ELOG = {2} ,({3})
34 = Controller ID: {0} Not enough controller memory
35 = Controller ID: {0} Patrol Read complete
36 = Controller ID: {0} Patrol Read paused
37 = Controller ID: {0} Patrol Read Rate changed: {1}%
38 = Controller ID: {0} Patrol Read resumed
39 = Controller ID: {0} Patrol Read started
40 = Controller ID: {0} Rebuild rate changed: {1}%
41 = Controller ID: {0} Reconstruction rate changed: {1}%
42 = Controller ID: {0} Shutdown command received from host
43 = Controller ID: {0} Test event: '{1}'
44 = Controller ID: {0} Time established since power on: TIME {1} {2} Seconds
45 = Controller ID: {0} User entered firmware debugger
46 = Controller ID: {0} Background Initialization aborted on VD: {1}
47 = Controller ID: {0} Background Initialization corrected medium error: (VD {1} Location {2}, PD {3} Location {4})
48 = Controller ID: {0} Background Initialization completed on VD: {1}
49 = Controller ID: {0} Background Initialization completed with uncorrectable errors on VD: {1}
50 = Controller ID: {0} Background Initialization detected uncorrectable multiple medium errors: (PD {1} Location {2}, VD {3})
51 = Controller ID: {0} Background Initialization failed on VD: {1}
52 = Controller ID: {0} Background Initialization progress: {1}%
53 = Controller ID: {0} Background Initialization started on VD:{1}
54 = Controller ID: {0} Policy change on VD: {1} Previous = {2} Now = {3}
55 = Controller ID: {0} OBSOLETE
56 = Controller ID: {0} Consistency Check aborted on VD: {1}
57 = Controller ID: {0} Consistency Check corrected medium error:(VD {1} Location {2}, PD {3} Location {4})
58 = Controller ID: {0} Consistency Check done on VD: {1}
59 = Controller ID: {0} Consistency Check done with corrections on VD: {1}, (corrections = {2})
60 = Controller ID: {0} Consistency Check detected uncorrectable multiple medium errors: (PD {1} Location {2}, VD {3})
61 = Controller ID: {0} Consistency Check failed on VD: {1}
62 = Controller ID: {0} Consistency Check completed with uncorrectable errors on VD: {1}
63 = Controller ID: {0} Consistency Check found inconsistent parity on VD strip: (VD = {1}, strip = {2})
64 = Controller ID: {0} Consistency Check inconsistency logging disabled, too many inconsistencies on VD: {1}
65 = Controller ID: {0} Consistency Check progress: VD = {1}
66 = Controller ID: {0} Consistency Check started on VD: {1}
67 = Controller ID: {0} Initialization aborted on VD: {1}
68 = Controller ID: {0} Initialization failed on VD: {1}
69 = Controller ID: {0} Initialization progress on VD: {1} Progress = {2}%
70 = Controller ID: {0} Fast initialization started on VD: {1}
71 = Controller ID: {0} Full initialization started on VD: {1}
72 = Controller ID: {0} Initialization complete on VD: {1}
73 = Controller ID: {0} Properties updated on VD: {1} Previous = {2} Now = {3}
74 = Controller ID: {0} Reconstruction complete: VD {1}
75 = Controller ID: {0} Reconstruction stopped due to unrecoverable errors: VD {1}
76 = Controller ID: {0} Reconstruct detected uncorrectable multiple medium errors: (VD {1} Location {2}, PD {3} Location {4})
77 = Controller ID: {0} Reconstruction progress: VD {1} Progress {2}%
78 = Controller ID: {0} Reconstruction resumed: VD {1}
79 = Controller ID: {0} Reconstruction resume failed due to configuration mismatch: VD {1}
80 = Controller ID: {0} Reconstruction started: VD {1}
81 = Controller ID: {0} State change on VD: {1} Previous = {2} Current = {3}
82 = Controller ID: {0} PD Clear aborted: {1}
83 = Controller ID: {0} PD Clear failed: {1} (Error {2})
84 = Controller ID: {0} PD Clear progress: {1} Progress = {2}%
85 = Controller ID: {0} PD Clear started: {1}
86 = Controller ID: {0} PD Clear completed: {1}
87 = Controller ID: {0} Error: {1} (Error {2})
88 = Controller ID: {0} Format complete: {1}
89 = Controller ID: {0} Format started: {1}
90 = Controller ID: {0} Hot Spare SMART polling failed: {1} (Error {2})
91 = Controller ID: {0} PD inserted: {1}
92 = Controller ID: {0} PD is not supported: {1}
93 = Controller ID: {0} Patrol Read corrected medium error: PD {1} Location {2}
94 = Controller ID: {0} Patrol Read progress: PD {1} Progress {2}%
95 = Controller ID: {0} Patrol Read found an uncorrectable medium error: PD {1} Location {2}
96 = Controller ID: {0} PD Predictive failure: {1}
97 = Controller ID: {0} Puncturing bad block: PD {1} Location {2}
98 = Controller ID: {0} Rebuild aborted by user: PD {1}
99 = Controller ID: {0} Rebuild complete on VD {1}
100 = Controller ID: {0} Rebuild complete {1}
101 = Controller ID: {0} Rebuild failed due to source drive error: PD {1}
102 = Controller ID: {0} Rebuild failed due to target drive error: PD {1}
103 = Controller ID: {0} Rebuild progress: PD {1} Progress {2}
104 = Controller ID: {0} Rebuild resumed: PD {1}
105 = Controller ID: {0} Rebuild started: PD {1}
106 = Controller ID: {0} Rebuild automatically started: PD {1}
107 = Controller ID: {0} Rebuild stopped due to loss of cluster ownership: PD {1}
108 = Controller ID: {0} Reassign write operation failed: PD {1} Location {2}
109 = Controller ID: {0} Unrecoverable medium error during rebuild: PD {1} Location {2}
110 = Controller ID: {0} Corrected medium error during recovery: PD {1} Location {2}
111 = Controller ID: {0} Unrecoverable medium error during recovery: PD {1} Location {2}
112 = Controller ID: {0} PD removed: {1}
113 = Controller ID: {0} Unexpected sense: PD = {1}, CDB = {2}, Sense = {3}
114 = Controller ID: {0} State change: PD = {1} Previous = {2} Current = {3}
115 = Controller ID: {0} State change by user: PD = {1} Previous = {2} Current = {3}
116 = Controller ID: {0} Redundant path broken: {1}
117 = Controller ID: {0} Redundant path restored: {1}
118 = Controller ID: {0} Dedicated Hot Spare no longer useful due to deleted array: PD = {1}
119 = Controller ID: {0} SAS topology error: Loop detected
120 = Controller ID: {0} SAS topology error: Device not addressable
121 = Controller ID: {0} SAS topology error: Multiple ports to the same SAS address
122 = Controller ID: {0} SAS topology error: Expander error
123 = Controller ID: {0} SAS topology error: SMP timeout
124 = Controller ID: {0} SAS topology error: Out of route entries
125 = Controller ID: {0} SAS topology error: Index not found
126 = Controller ID: {0} SAS topology error: SMP function failed
127 = Controller ID: {0} SAS topology error: SMP CRC error
128 = Controller ID: {0} SAS topology error: Multiple subtractive
129 = Controller ID: {0} SAS topology error: Table to table
130 = Controller ID: {0} SAS topology error: Multiple paths
131 = Controller ID: {0} Unable to access device PD {1}
132 = Controller ID: {0} Dedicated Hot Spare created: PD {1}
133 = Controller ID: {0} Dedicated Hot Spare disabled: PD {1}
134 = Controller ID: {0} Dedicated Hot Spare no longer useful for all arrays: {1}
135 = Controller ID: {0} Global Hot Spare created: {1}
136 = Controller ID: {0} Global Hot Spare disabled: {1}
137 = Controller ID: {0} Global Hot Spare does not cover all arrays {1}
138 = Controller ID: {0} Created VD: {1}
139 = Controller ID: {0} Deleted VD: {1}
140 = Controller ID: {0} VD Marked inconsistent due to active writes at shutdown: VD {1}
141 = Controller ID: {0} Battery Present
142 = Controller ID: {0} Battery Not Present
143 = Controller ID: {0} New Battery Detected
144 = Controller ID: {0} Battery has been replaced
145 = Controller ID: {0} Battery temperature is high
146 = Controller ID: {0} Battery voltage low
147 = Controller ID: {0} Battery started charging
148 = Controller ID: {0} Battery is discharging
149 = Controller ID: {0} Battery temperature is normal
150 = Controller ID: {0} Battery needs to be replaced, SOH Bad
151 = Controller ID: {0} Battery relearn started
152 = Controller ID: {0} Battery relearn in progress
153 = Controller ID: {0} Battery relearn completed
154 = Controller ID: {0} Battery relearn timed out
155 = Controller ID: {0} Battery relearn pending: Battery is under charge
156 = Controller ID: {0} Battery relearn postponed
157 = Controller ID: {0} Battery relearn will start in 4 days
158 = Controller ID: {0} Battery relearn will start in 2 days
159 = Controller ID: {0} Battery relearn will start in 1 day
160 = Controller ID: {0} Battery relearn will start in 5 hours
161 = Controller ID: {0} Battery removed
162 = Controller ID: {0} Current capacity of the battery is below threshold
163 = Controller ID: {0} Current capacity of the battery is above threshold
164 = Controller ID: {0} SES enclosure discovered: {1}
165 = Controller ID: {0} SAF-TE enclosure discovered: {1}
166 = Controller ID: {0} Communication lost on enclosure: {1}
167 = Controller ID: {0} Communication restored on enclosure: {1}
168 = Controller ID: {0} Fan failed on enclosure: {1} Fan {2}
169 = Controller ID: {0} Fan inserted on enclosure: {1} Fan {2}
170 = Controller ID: {0} Fan removed on enclosure: {1} Fan {2}
171 = Controller ID: {0} Power supply failed on enclosure: {1} Power Supply {2}
172 = Controller ID: {0} Power supply inserted on enclosure: {1} Power Supply {2}
173 = Controller ID: {0} Power supply removed on enclosure: {1} Power Supply {2}
174 = Controller ID: {0} ESM failed on enclosure: {1} ESM {2}
175 = Controller ID: {0} ESM inserted on enclosure: {1} ESM {2}
176 = Controller ID: {0} SIM removed on enclosure: {1} ESM {2}
177 = Controller ID: {0} Temperature sensor below warning threshold on enclosure: {1} Sensor {2}
178 = Controller ID: {0} Temperature sensor below error threshold on enclosure: {1} Sensor {2}
179 = Controller ID: {0} Temperature sensor above warning threshold on enclosure: {1} Sensor {2}
180 = Controller ID: {0} Temperature sensor above error threshold on enclosure: {1} Sensor {2}
181 = Controller ID: {0} Enclosure shutdown: {1}
182 = Controller ID: {0} Too many enclosures connected to port. Enclosure not supported: {1}
183 = Controller ID: {0} Firmware mismatch on enclosure: {1}
184 = Controller ID: {0} Sensor bad on enclosure: {1} Sensor {2}
185 = Controller ID: {0} Phy is bad on enclosure: {1} PHY {2}
186 = Controller ID: {0} Unstable Enclosure: {1}
187 = Controller ID: {0} Hardware error on enclosure: {1}
188 = Controller ID: {0} No response from enclosure: {1}
189 = Controller ID: {0} SAS/SATA mixing not supported in enclosure; disabled PD: {1}
190 = Controller ID: {0} Unsupported hotplug was detected on SES enclosure: {1}
191 = Controller ID: {0} Clustering enabled
192 = Controller ID: {0} Clustering disabled
193 = Controller ID: {0} PD too small to be used for auto-rebuild: {1}
194 = Controller ID: {0} BBU enabled; changing WT logical drives to WB
195 = Controller ID: {0} BBU disabled; changing WB logical drives to WT, Forced WB VDs are not affected
196 = Controller ID: {0} Bad block table is 80% full on PD: {1}
197 = Controller ID: {0} Bad block table is full; unable to log block: PD = {1}, Block = {2}
198 = Controller ID: {0} Consistency Check Aborted Due to Ownership Loss on VD: {1}
199 = Controller ID: {0} Background Initialization (BGI) aborted due to ownership loss on VD: {1}
200 = Controller ID: {0} Battery/charger problems detected; SOH Bad
201 = Controller ID: {0} Single-bit ECC error; warning threshold exceeded: ECAR = {1} ELOG = {2} ({3})
202 = Controller ID: {0} Single-bit ECC error; critical threshold exceeded: ECAR = {1} ELOG = {2} ({3})
203 = Controller ID: {0} Single-bit ECC error; further reporting disabled: ECAR = {1} ELOG = {2} ({3})
204 = Controller ID: {0} Power supply switched off for enclosure: {1} Power Supply {2}
205 = Controller ID: {0} Power supply switched on for enclosure: {1} Power Supply {2}
206 = Controller ID: {0} Power supply cable removed on enclosure: {1} Power Supply {2}
207 = Controller ID: {0} Power supply cable inserted on enclosure: {1} Power Supply {2}
208 = Controller ID: {0} Fan returned to normal on enclosure: {1} Fan {2}
209 = Controller ID: {0} BBU Retention test was initiated on previous boot
210 = Controller ID: {0} BBU Retention test passed
211 = Controller ID: {0} BBU Retention test failed!
212 = Controller ID: {0} NVRAM Retention test was initiated on previous boot
213 = Controller ID: {0} NVRAM Retention test passed
214 = Controller ID: {0} NVRAM Retention test failed!
215 = Controller ID: {0} Successfully completed test: {1} passes = {2}
216 = Controller ID: {0} FAILED Test: {1} Pass = {2} Fail Data:ErrorOffset = {3} GoodData = {4} BadData = {5}
217 = Controller ID: {0} Self check diagnostics completed
218 = Controller ID: {0} Foreign Configuration Detected
219 = Controller ID: {0} Foreign Configuration Imported
220 = Controller ID: {0} Foreign Configuration Cleared
221 = Controller ID: {0} NVRAM is corrupt; reinitializing
222 = Controller ID: {0} NVRAM mismatch occurred
223 = Controller ID: {0} Link lost on SAS wide port: {1} PHY = {2}
224 = Controller ID: {0} Link restored on SAS wide port: {1} PHY = {2}
225 = Controller ID: {0} Allowed error rate exceeded on SAS port: {1} PHY = {2}
226 = Controller ID: {0} Bad block reassigned: {1} Previous = {2} Current = {3}
227 = Controller ID: {0} Controller Hot Plug detected
228 = Controller ID: {0} Temperature sensor differential detected on enclosure: {1} Sensor {2}
229 = Controller ID: {0} Disk test cannot start. No qualifying disks found
230 = Controller ID: {0} Time duration provided by host is not sufficient for self check
231 = Controller ID: {0} Marked Missing on array: {1} Array {2} Row {3}
232 = Controller ID: {0} Replaced Missing on array: {1} Array {2} Row {3}
233 = Controller ID: {0} Temperature returned to normal on enclosure: {1} Space {2}
234 = Controller ID: {0} Firmware download in progress on enclosure: {1}
235 = Controller ID: {0} Firmware download failed on enclosure: {1}
236 = Controller ID: {0} Drive is not certified: {1}
237 = Controller ID: {0} Dirty Cache data discarded by user
238 = Controller ID: {0} PDs missing from configuration at boot
239 = Controller ID: {0} VDs missing drives and will go offline at boot {1}
240 = Controller ID: {0} VDs missing at boot {1}
241 = Controller ID: {0} Previous configuration completely missing at boot
242 = Controller ID: {0} Battery charge complete
243 = Controller ID: {0} Fan speed changed on enclosure: {1} Fan {2}
244 = Controller ID: {0} Dedicated spare imported as global due to missing arrays PD {1}
245 = Controller ID: {0} PD rebuild not possible as SAS/SATA is not supported in an array PD {1}
246 = Controller ID: {0} SEP has been rebooted as a part of enclosure firmware download. SEP will be unavailable until reboot completes. SEP {1}
247 = Controller ID: {0} Device inserted Device Type: {1} Device Id: {2}
248 = Controller ID: {0} Device removed Device Type: {1} Device Id: {2}
249 = Controller ID: {0} VD is now OPTIMAL VD {1}
250 = Controller ID: {0} VD is now PARTIALLY DEGRADED VD {1}
251 = Controller ID: {0} VD is now DEGRADED VD {1}
252 = Controller ID: {0} VD is now OFFLINE VD {1}
253 = Controller ID: {0} Battery requires reconditioning; please initiate a LEARN cycle
254 = Controller ID: {0} VD disabled because RAID-5 is not supported by this RAID key VD {1}
255 = Controller ID: {0} VD disabled because RAID-6 is not supported by this controller VD {1}
256 = Controller ID: {0} VD disabled because SAS drives are not supported by this RAID key VD {1}
257 = Controller ID: {0} PD missing VD {1}
258 = Controller ID: {0} Puncturing of LBAs enabled
259 = Controller ID: {0} Puncturing of LBAs disabled
260 = Controller ID: {0} Enclosure ESM not installed {1} ESM {2}
261 = Controller ID: {0} Package version {1}
262 = Controller ID: {0} Global affinity Hot Spare commissioned in a different enclosure {1}
263 = Controller ID: {0} Foreign configuration table overflow
264 = Controller ID: {0} Partial foreign configuration imported, PDs not imported: {1}
265 = Controller ID: {0} Connector is active: {1}
266 = Controller ID: {0} Board Revision: {1}
267 = Controller ID: {0} Command timeout on PD: PD = {1}, CDB = {2}, Sense = {3}, Path = {4}
268 = Controller ID: {0} PD Reset: PD = {1}, Error = {2}, Path = {3}
269 = Controller ID: {0} VD bad block table is 80% full: VD {1}
270 = Controller ID: {0} VD bad block table is full - unable to log block: VD {1}
271 = Controller ID: {0} Uncorrectable medium error logged: (VD {1} Location {2}, PD {3} Location {4})
272 = Controller ID: {0} VD medium error corrected: VD {1} Location {2}
273 = Controller ID: {0} PD Bad block table is 100% full: PD {1}
274 = Controller ID: {0} VD Bad block table is 100% full: VD {1}
275 = Controller ID: {0} Controller needs replacement since IOP is faulty
276 = Controller ID: {0} Replace drive operation started on PD: {1} Source PD: {2}
277 = Controller ID: {0} Replace drive operation aborted on PD: {1} Source PD: {2}
278 = Controller ID: {0} Replace drive operation completed on PD: {1} Source PD: {2}
279 = Controller ID: {0} Replace drive operation progress on PD: {1} Progress {2}%
280 = Controller ID: {0} Replace drive operation resumed on PD: {1} Source PD: {2}
281 = Controller ID: {0} Replace drive operation automatically started on PD: {1} Source PD: {2}
282 = Controller ID: {0} Replace drive operation failed due to source drive error on PD: {1} Source PD: {2}
283 = Controller ID: {0} Early power off warning was unsuccessful
284 = Controller ID: {0} BBU FRU is: {1}
285 = Controller ID: {0} PD FRU is: PD: {1} FRU: {1}
286 = Controller ID: {0} Controller hardware revision id is: {1}
287 = Controller ID: {0} Foreign import shall result in a backward incompatible upgrade of configuration metadata
288 = Controller ID: {0} Redundant path restored PD: {1} Path: {2} SAS Address: {3}
289 = Controller ID: {0} Redundant path broken PD: {1} Path: {2} SAS Address: {3}
290 = Controller ID: {0} Redundant enclosure module inserted Redundant: {1} Primary: {2}
291 = Controller ID: {0} Redundant enclosure module removed Redundant: {1} Primary: {2}
292 = Controller ID: {0} Patrol Read can't be started, as PDs are either not ONLINE, or are in a VD with an active process, or are in an excluded VD
293 = Controller ID: {0} Replace drive operation aborted by user on PD: {1} Source PD: {2}
294 = Controller ID: {0} Replace drive operation aborted on the hot spare as hot spare needed for rebuild. Hot Spare PD: {1} Source PD: {2}
295 = Controller ID: {0} Replace drive operation aborted as rebuild required in the array. PD: {1} Source PD: {2}
296 = Controller ID: {0} Controller cache discarded for missing or offline VD VD {1}
297 = Controller ID: {0} Replace drive operation cannot be started as drive is too small. PD: {1} Source PD: {2}
298 = Controller ID: {0} Replace drive operation cannot be started as SAS/SATA is not supported in an array. PD: {1} Source PD: {2}
299 = Controller ID: {0} Microcode update started on PD: {1}
300 = Controller ID: {0} Microcode update completed on PD: {1}
301 = Controller ID: {0} Microcode update timeout on PD: {1}
302 = Controller ID: {0} Microcode update failed on PD: {1}
303 = Controller ID: {0} Controller properties changed
304 = Controller ID: {0} Patrol Read properties changed
305 = Controller ID: {0} CC Schedule properties changed
306 = Controller ID: {0} Battery properties changed
307 = Controller ID: {0} Periodic Battery Relearn is pending. Please initiate manual learn cycle as Automatic learn is not enabled
308 = Controller ID: {0} Drive security key created
309 = Controller ID: {0} Drive security key backed up
310 = Controller ID: {0} Drive security key from escrow, verified
311 = Controller ID: {0} Drive security key changed
312 = Controller ID: {0} Drive security key, re-key operation failed
313 = Controller ID: {0} Drive security key is invalid
314 = Controller ID: {0} Drive security key destroyed
315 = Controller ID: {0} Drive security key from escrow is invalid
316 = Controller ID: {0} VD is now secured: VD {1}
317 = Controller ID: {0} VD is partially secured: VD {1}
318 = Controller ID: {0} PD security activated: PD {1}
319 = Controller ID: {0} PD security disabled: PD {1}
320 = Controller ID: {0} PD is reprovisioned: PD {1}
321 = Controller ID: {0} PD security key changed: PD {1}
322 = Controller ID: {0} Security subsystem problems detected for PD: PD {1}
323 = Controller ID: {0} Controller cache pinned for missing or offline VD: VD {1}
324 = Controller ID: {0} Controller cache pinned for missing or offline VDs: VD {1}
325 = Controller ID: {0} Controller cache discarded by user for missing VDs: VD {1}
326 = Controller ID: {0} Controller cache destaged for VD: VD {1}
327 = Controller ID: {0} Consistency Check started on an inconsistent VD: VD {1}
328 = Controller ID: {0} Drive security key failure, cannot access secured configuration
329 = Controller ID: {0} Drive security pass phrase from user is invalid
330 = Controller ID: {0} Detected error with the remote battery connector cable
331 = Controller ID: {0} Power state change on PD = {1} Previous = {2} Current = {3}
332 = Controller ID: {0} Enclosure element status changed Enclosure {1} SES code {2}
333 = Controller ID: {0} Rebuild is not allowed on PD as HDD/SSD mix is not supported in VDs. PD: {1}
334 = Controller ID: {0} Replace drive operation is not allowed on PD as HDD/SSD mix is not supported in VDs. PD: {1} Source PD: {2}
335 = Controller ID: {0} VD Bad block table is cleared. VD: {1}
336 = Controller ID: {0} SAS topology error: {1}
337 = Controller ID: {0} VD cluster of medium errors corrected: (VD {1} Location {2}, PD {3} Location {4})
338 = Controller ID: {0} Controller requests a host bus rescan
339 = Controller ID: {0} Controller repurposed and factory defaults restored
340 = Controller ID: {0} Drive security key binding updated
341 = Controller ID: {0} Drive security is in EKM mode
342 = Controller ID: {0} Drive security failed to communicate with EKMS
343 = Controller ID: {0} PD needs key to be {1} PD: {2} KeyId Length: {3}
344 = Controller ID: {0} VD secure failed: {1}
345 = Controller ID: {0} Controller encountered a fatal error and was reset
346 = Controller ID: {0} Snapshot enabled on VD {1} SnapShot Repository VD: {2}
347 = Controller ID: {0} Snapshot disabled by the user on VD {1} SnapShot Repository VD: {2}
348 = Controller ID: {0} Snapshot disabled on VD {1} SnapShot Repository VD: {2}
349 = Controller ID: {0} Snapshot Point In Time created on VD {1} PIT creation time {2}
350 = Controller ID: {0} Snapshot Point In Time deleted on VD {1} PIT creation time {2}
351 = Controller ID: {0} Snapshot View created on VD {1} PIT creation time {2} Snapshot view creation time {3}
352 = Controller ID: {0} Snapshot View deleted on VD {1} PIT creation time {2} Snapshot view creation time {3}
353 = Controller ID: {0} Snapshot rollback started for Point In Time on VD {1} PIT creation time {2}
354 = Controller ID: {0} Snapshot rollback internally aborted for Point In Time on VD {1} PIT creation time {2}
355 = Controller ID: {0} Snapshot rollback completed for Point In Time on VD {1} PIT creation time {2}
356 = Controller ID: {0} Snapshot rollback progress on Point In Time on VD {1} PIT creation time {2} Progress = {3}
357 = Controller ID: {0} Snapshot repository 80% full on VD {1} SnapShot Repository VD: {2}
358 = Controller ID: {0} Snapshot repository full on VD {1} SnapShot Repository VD: {2}
359 = Controller ID: {0} Snapshot View 80% full on VD {1} SnapShot Repository VD: {2}
360 = Controller ID: {0} Snapshot view full on VD {1} SnapShot Repository VD: {2}
361 = Controller ID: {0} Repository lost for VD {1}
362 = Controller ID: {0} Repository restored for VD {1}
363 = Controller ID: {0} Snapshot encountered an unexpected internal error: {1}
364 = Controller ID: {0} Auto Snapshot enabled on VD {1} SnapShot Repository VD: {2}
365 = Controller ID: {0} Auto Snapshot disabled on VD {1} SnapShot Repository VD: {2}
366 = Controller ID: {0} Configuration command could not be committed to disk, please retry!
367 = Controller ID: {0} COD on PD updated as it was stale. PD: {1}
368 = Controller ID: {0} Power state change failed on PD = {1} Previous = {2} Current = {3}
369 = Controller ID: {0} VD is not available. VD: {1}
370 = Controller ID: {0} VD is available. VD: {1}
371 = Controller ID: {0} VD is used for CacheCade. VD: {1} Capacity - Logical Blocks: {2}
372 = Controller ID: {0} VD is being cached in CacheCade. VD: {1} SSC VD {2}
373 = Controller ID: {0} VD is no longer being cached in CacheCade. VD: {1} SSC VD {2}
374 = Controller ID: {0} Snapshot deleted due to resource constraints on VD {1} SnapShot Repository VD: {2}
375 = Controller ID: {0} Auto Snapshot failed for VD {1} SnapShot Repository VD: {2}
376 = Controller ID: {0} Controller reset on-board expander
377 = Controller ID: {0} CacheCade VD capacity changed. VD: {1} Capacity - Logical Blocks: {2}
378 = Controller ID: {0} Battery cannot initiate transparent learn cycles
379 = Controller ID: {0} Activation Key was applied Action {1} MegaRAID Advanced Software(s): {2}
380 = Controller ID: {0} Snapshot schedule properties changed on VDs: {1}
381 = Controller ID: {0} Snapshot scheduled action is due - Schedule timer expired on VDs: {1}
382 = Controller ID: {0} Performance Metrics: collection command: {1}
383 = Controller ID: {0} MegaRAID Advanced Software Options have been transferred Action {1} MegaRAID Advanced Software(s): {2}
384 = Controller ID: {0} Advanced Software Options Serial number: {1}
385 = Controller ID: {0} Advanced Software Options Serial number mismatched. Key vault Serial number is:
386 = Controller ID: {0} Battery cannot support data retention for more than few hours. Hour: {1} Please replace the battery
387 = Controller ID: {0} Power Policy changed on VD : {1} Previous = {2} Now = {3}
388 = Controller ID: {0} Cannot transition to max power savings on VD : {1}
389 = Controller ID: {0} Host driver is loaded and operational
390 = Controller ID: {0} Mirror broken on VD : {1}
391 = Controller ID: {0} Mirror joined on VD : {1}
392 = Controller ID: {0} Link failed on Wide Port {1} Link {2}
393 = Controller ID: {0} Link restored on Wide Port {1} Link {2}
394 = Controller ID: {0} Memory module FRU is {1}
395 = Controller ID: {0} Cache-vault power pack is sub-optimal. Please replace the pack.
396 = Controller ID: {0} Foreign configuration auto-import did not import any drives
397 = Controller ID: {0} Cache-vault microcode update required.
398 = Controller ID: {0} {1} CacheCade(TM) capacity exceeds maximum allowed size, extra capacity is not used
399 = Controller ID: {0} Protection information lost on VD : {1}
400 = Controller ID: {0} Diagnostics passed for PD : {1}
401 = Controller ID: {0} Diagnostics failed for PD : {1}
402 = Controller ID: {0} Server Power capability Diagnostic Test Started
403 = Controller ID: {0} Drive Cache settings enabled during rebuild for PD : {1}
404 = Controller ID: {0} Drive Cache settings restored after rebuild for PD : {1}
405 = Controller ID: {0} {1} PD commissioned as Emergency spare
406 = Controller ID: {0} Reminder: Potential non-optimal configuration due to PD commissioned as emergency spare {1}
407 = Controller ID: {0} Consistency Check suspended on VD : {1}
408 = Controller ID: {0} Consistency Check resumed on VD : {1}
409 = Controller ID: {0} Background Initialization suspended on VD : {1}
410 = Controller ID: {0} Background Initialization resumed on VD : {1}
411 = Controller ID: {0} Reconstruction suspended on VD : {1}
412 = Controller ID: {0} Rebuild suspended on PD : {1}
413 = Controller ID: {0} Replace drive operation suspended on PD : {1}
414 = Controller ID: {0} Reminder: Consistency Check suspended on VD : {1}
415 = Controller ID: {0} Reminder: Background Initialization suspended on VD : {1}
416 = Controller ID: {0} Reminder: Reconstruction suspended on VD : {1}
417 = Controller ID: {0} Reminder: Rebuild suspended on PD : {1}
418 = Controller ID: {0} Reminder: Replace drive operation suspended on PD : {1}
419 = Controller ID: {0} Reminder: Patrol Read suspended
420 = Controller ID: {0} Erase aborted on PD : {1}
421 = Controller ID: {0} Erase failed on PD : {1} (Error {2})
422 = Controller ID: {0} Erase progress on PD : {1} Progress = {2}
423 = Controller ID: {0} Erase started on PD : {1}
424 = Controller ID: {0} Erase completed on PD : {1}
425 = Controller ID: {0} Erase aborted on VD : {1}
426 = Controller ID: {0} Erase failed on VD : {1}
427 = Controller ID: {0} Erase progress on VD : {1} Progress = {2}
428 = Controller ID: {0} Erase started on VD : {1}
429 = Controller ID: {0} Erase complete on VD : {1}
430 = Controller ID: {0} Potential leakage during erase on VD : {1}
431 = Controller ID: {0} Battery charging was suspended due to high battery temperature
432 = Controller ID: {0} NVCache firmware update was successful
433 = Controller ID: {0} NVCache firmware update failed
434 = Controller ID: {0} VD : {1} access blocked as cached data in CacheCade(TM) is unavailable
435 = Controller ID: {0} CacheCade(TM) disassociate started on VD : {1}
436 = Controller ID: {0} CacheCade(TM) disassociate completed on VD : {1}
437 = Controller ID: {0} CacheCade(TM) disassociate failed on VD : {1}
438 = Controller ID: {0} CacheCade(TM) disassociate progress on VD : {1} Progress = {2}
439 = Controller ID: {0} CacheCade(TM) disassociate aborted by user on VD : {1}
440 = Controller ID: {0} Link speed changed on SAS port {1} PHY = {2}
441 = Controller ID: {0} Advanced Software Options was deactivated for Premium Feature(s): - {1}
442 = Controller ID: {0} VD : {1} is now accessible
443 = Controller ID: {0} VD : {1} is using CacheCade(TM)
444 = Controller ID: {0} VD : {1} is no longer using CacheCade(TM)
445 = Controller ID: {0} Patrol Read aborted on PD : {1}
446 = Controller ID: {0} Transient error detected while communicating with PD : {1}
447 = Controller ID: {0} PI error in cache for LD : {1} at LBA : {2}
448 = Controller ID: {0} Flash downloaded image is not supported
449 = Controller ID: {0} BBU mode selected - {1}
450 = Controller ID: {0} Periodic Battery Relearn was missed and Rescheduled to : {1}
451 = Controller ID: {0} Controller reset requested by host.
452 = Controller ID: {0} Controller reset requested by host, completed.
453 = Controller ID: {0} L3 cache error has been detected.
454 = Controller ID: {0} L2 cache error has been detected.
455 = Controller ID: {0} Controller booted in headless mode with errors.
456 = Controller ID: {0} Controller booted to safe mode due to critical errors.
457 = Controller ID: {0} Warning Error during boot : {1}%
458 = Controller ID: {0} Critical Error during boot : {1}%
459 = Controller ID: {0} Fatal Error during boot : {1}%
#HAMR Events
460 = Controller ID: {0} Peer Controller entered HA Domain.
461 = Controller ID: {0} Peer Controller exited HA Domain.
462 = Controller ID: {0} Peer Controller now manages PD: {1}
463 = Controller ID: {0} Local Controller now manages PD: {1}
464 = Controller ID: {0} Peer Controller now manages VD: {1}
465 = Controller ID: {0} Local Controller now manages VD: {1}
466 = Controller ID: {0} Target ID conflict detected on VD:{1} access is restricted from Peer controller
467 = Controller ID: {0} Shared access policy set for VD: {1}
468 = Controller ID: {0} Exclusive access policy set for VD: {1}
469 = Controller ID: {0} VD is incompatible in the HA Domain. VD: {1}
470 = Controller ID: {0} Peer controller is incompatible.
471 = Controller ID: {0} Controllers in the HA domain are incompatible.
472 = Controller ID: {0} Controller property mismatch detected with Peer controller.
473 = Controller ID: {0} FW version does not match Peer controller.
474 = Controller ID: {0} Advanced Software Option mismatch detected with Peer controller.
475 = Controller ID: {0} Cache mirroring is Online.
476 = Controller ID: {0} Cache mirroring is Offline.
477 = Controller ID: {0} Cached data from Peer controller is unavailable for VD: {1} access policy is set to Blocked.
478 = Controller ID: {0} Cache-vault power pack is not supported. Please replace the pack.
479 = Controller ID: {0} Temperature is above warning threshold on PD: {1} Temperature: {2} Celsius
480 = Controller ID: {0} Temperature is above critical threshold on PD: {1} Temperature: {2} Celsius
481 = Controller ID: {0} Temperature is normal on PD: {1} Temperature: {2} Celsius
482 = Controller ID: {0} IOs are being throttled on PD: {1}
483 = Controller ID: {0} IOs are normal on PD: {1}
484 = Controller ID: {0} Life left on PD: {1} (Life Left: {2}% and Life Left Thresholds - Warning: {3}%, Critical: {4}%)
485 = Controller ID: {0} Life is below Optimal on PD: {1} (Life Left: {2}% and Life Left Thresholds - Warning: {3}%, Critical:{4}%)
486 = Controller ID: {0} Life is Critical on PD: {1} (Life Left: {2}% and Life Left Thresholds - Warning: {3}%, Critical:{4}%)
487 = Controller ID: {0} PD failure, device locked-up. PD: {1}
488 = Controller ID: {0} Host driver needs to be upgraded {1}
489 = Controller ID: {0} Direct communication with peer controller(s) was not established. Please check proper cable connections
490 = Controller ID: {0} Firmware image does not contain signed component
491 = Controller ID: {0} Authentication failure of the signed firmware image
492 = Controller ID: {0} Setted VD as boot device. VD: {1}
493 = Controller ID: {0} Setted PD as boot device. PD: {1}
494 = Controller ID: {0} The BBU temperature is changed to {1} Celsius
495 = Controller ID: {0} The Controller temperature is changed to {1} Celsius
496 = Controller ID: {0} NVCache capacity is too less to support data backup. Write-back VDs will be converted to write-through
497 = Controller ID: {0} NVCache data backup capacity has decreased, consider replacement
498 = Controller ID: {0} NVCache device failed, cannot support data retention
499 = Controller ID: {0} Boot Device reset, setting target ID as invalid
500 = Controller ID: {0} Write back Nytro cache size mismatch between the servers. The Nytro cache size was adjusted to %ld GB
501 = Controller ID: {0} VD %ld is not shared between servers but assigned for caching. Write back Nytro cache content of the VD will be mirrored
502 = Controller ID: {0} Power {1} watts usage base IOs throttle started
503 = Controller ID: {0} Power base IOs throttle stopped
504 = Controller ID: {0} Controller tunable parameter(s) changed
505 = Controller ID: {0} Controller operating temperature within normal range, full operation restored
506 = Controller ID: {0} Controller temperature threshold exceeded. This may indicate inadequate system cooling. Switching to low performance mode
507 = Controller ID: {0} Controller supports HA mode, currently functioning with HA feature set
508 = Controller ID: {0} Controller supports HA mode, currently functioning with single controller feature set
509 = Controller ID: {0} Cache-vault components mismatch. Write-back VDs will be converted write-through
510 = Controller ID: {0} Controller has entered into maintenance mode {1}
511 = Controller ID: {0} Controller has returned to normal mode
512 = Controller ID: {0} Topology is in {1} mode
513 = Controller ID: {0} Cannot enter {1} mode because {2} LD {3} would not be supported
514 = Controller ID: {0} Cannot enter {1} mode because {2} PD {3} would not be supported
515 = Controller ID: {0} Cache Flush started
516 = Controller ID: {0} Cache Flush finished
517 = Controller ID: {0} Cache Flush aborted by user
518 = Controller ID: {0} Configuration automatically created by {1}
523 = Controller ID: {0} Peer controller security key mismatch
524 = Controller ID: {0} Peer controller security key match
525 = Controller ID: {0} Compatible in the HA domain
# CCoH related events
49152 = Cache Group: Added Cache Device {0}
49153 = Cache Group: Removed Cache Device {0}
49154 = Cache Group: Added VD {0}
49155 = Cache Group: Removed VD {0}
49156 = Cache Group: VD went Offline. VD: {0}
49157 = Cache Group: VD is Ready for Online. VD: {0}
49158 = Cache Group: VD is Online. VD: {0}
# Warhawk related events
65522 = Controller ID: {0} SSD is in unlocked state. Device Id: {1} Encl Index: {2} Slot Number {3}
65523 = Controller ID: {0} SSD is in locked state. Device Id: {1} Encl Index: {2} Slot Number {3}
65525 = Controller ID: {0} Temperature has exceeded critical temperature threshold Flags: {1} SensorOrSlot: {2} Temperature: {3} Threshold: {4} Device Id: {5}
65526 = Controller ID: {0} Temperature has exceeded warning temperature threshold Flags: {1} SensorOrSlot: {2} Temperature: {3} Threshold: {4} Device Id: {5}
65527 = Controller ID: {0} Power throttling is now removed Percent Power Throttled: {1} PCI Slot Available Power: {2}
65528 = Controller ID: {0} Percent Power Throttled: {1} PCI Slot Available Power: {2}
65529 = Controller ID: {0} Temperature has exceeded Critical level on Sensor: {1} Threshold: {2} Temperature: {3}
65530 = Controller ID: {0} Temperature has exceeded Warning level on Sensor: {1} Threshold: {2} Temperature: {3}
65531 = Controller ID: {0} The Backup Rail Monitor has failed
65532 = Controller ID: {0} SSD Life is exhausted on Slot: {1} Device Id: {2} Device Life: {3} Warning Level: {4} Error Level: {5}
65533 = Controller ID: {0} SSD Life is at warning level on Slot: {1} Device Id: {2} Device Life: {3} Warning Level: {4} Error Level: {5}
65534 = Controller ID: {0} SSD throttling is now removed on Slot: {1} Device Id: {2} Throttle: {3}
65535 = Controller ID: {0} SSD is being throttled on Slot: {1} Device Id: {2} Throttle: {3}